Wissenschaftliche Kurzinfos (Abstracts) zur digitalen Zahnersatzfertigung auf Implantaten:

CAD/CAM - Seite 5

Freitag, 07. August 2015

Ji MK, Park JH, Park SW, Yun KD, Oh GJ, Lim HP.
Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crowns. 
J Adv Prosthodont. 2015 Aug;7(4):271-7.

Freitag, 07. August 2015

Pozzi A, Tallarico M, Barlattani A.
Monolithic Lithium Disilicate Full-Contour Crowns Bonded on CAD/CAM Zirconia Complete-Arch Implant Bridges With 3 to 5 Years of Follow-Up.
J Oral Implantol. 2015 Aug;41(4):450-8.

Samstag, 11. April 2015

Anadioti E, Aquilino SA, Gratton DG, Holloway JA, Denry IL, Thomas GW, Qian F.

Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions.
J Prosthet Dent. 2015 Apr;113(4):304-9.

Donnerstag, 26. März 2015

Katsoulis J, Müller P, Mericske-Stern R, Blatz MB.
CAD/CAM fabrication accuracy of long- vs. short-span implantsupported FDPs.
Clin Oral Implants Res. 2015 Mar;26(3):245-9.

Samstag, 14. März 2015

Katsoulis J, Mericske-Stern R, Enkling N, Katsoulis K, Blatz MB.
In vitro precision of fit of computer-aided designed and computer-aided manufactured titanium screw-retained fixed dental prostheses before and after ceramic veneering.
Clin Oral Implants Res. 2015;26(1):44-9.

Donnerstag, 05. März 2015

Lins L, Bemfica V, Queiroz C, Canabarro A.
In vitro evaluation of the internal and marginal misfit of CAD/ CAM zirconia copings.
J Prosthet Dent. 2015 Mar;113(3):205-11.

Samstag, 17. Januar 2015

Pozzi A, Holst S, Fabbri G, Tallarico M.
Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/ template-guided surgery: a retrospective study with a follow-up between 3 and 5 years.
Clin Implant Dent Relat Res. 2015 Jan;17 Suppl 1:e86-96.

Mittwoch, 14. Januar 2015

de França DG, Morais MH, das Neves FD, Barbosa GA.
Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses.
J Prosthet Dent. 2015 Jan;113(1):22-8.

Freitag, 09. Januar 2015

Katsoulis J, Wälchli J, Kobel S, Gholami H, Mericske-Stern R.
Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.
Clin Implant Dent Relat Res. 2015 Jan;17 Suppl 1:e75-85.

Mittwoch, 03. Dezember 2014

Abduo J.
Fit of CAD/CAM implant frameworks: a comprehensive review.
J Oral Implantol. 2014 Dec;40(6):758-66.